§ 6-392. Amendments.  


Latest version.
  • The International Residential Code/2006 is amended and revised in the following respects:

    Section 101.1 (page 1) Insert: City of Carthage

    Section 104.11 (page 2) Insert: The alternative method commonly known as "pole barn" or "Laminated pole" type structures shall be limited to commercial buildings and accessory buildings only and not for residential dwelling units.

    Section 105.2 (page 3) Delete: Item #2, #5 and #9 in their entirety

    Section 106 (page 4) Delete in its entirety

    Section 107.3 (page 5) Delete: "ICC Electrical Code" and Insert: "2008 National Electrical Code"

    Table 301.2(1) (page 24) Insert: 201b ground snow load, 90 mph wind speed, B seismic design category, severe weathering, 30 inch frost line depth, moderate to heavy termite, slight [to] moderate decay

    Section 403.1.1 (page 68) Insert: All footings for residential construction are to be at least 14 inches in width and 10 inches in thickness

    Section 3301.1 (page 471) Insert: Chapters 33 through 42 of the International Residential Code Shall be Amended to include any and all applicable sections of the 2008 National Electric Code.

(Ord. No. 10-49, § III, 12-28-10)